{"id":93,"date":"2022-09-07T09:46:54","date_gmt":"2022-09-07T00:46:54","guid":{"rendered":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en2\/?post_type=case&#038;p=93"},"modified":"2022-09-07T10:01:42","modified_gmt":"2022-09-07T01:01:42","slug":"bulk-steady-current","status":"publish","type":"case","link":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/case\/bulk-steady-current\/","title":{"rendered":"DC current field analysis of bulk conductors"},"content":{"rendered":"<h3>Summary<\/h3>\n<p>For analysis of bulk conductors, including eddy currents, <a href=\"\/product\/EMSolution\/en\/case\/sufcur\/\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline\"><font color=\"Red\">&quot;SUFCUR&quot;<\/font><\/a> is available. However, SUFCUR cannot be used in static magnetic field analysis (STATIC). For STATIC, <a href=\"\/product\/EMSolution\/en\/case\/phicoil\/\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline\"><font color=\"Red\">&quot;PHICOIL&quot;<\/font><\/a> can be used as a similar function, but it is designed for coils and cannot be applied to conductors in contact with members with different conductivities. We now introduce DCCURR, a current field source that extends PHICOIL. DCCURR performs calculations similar to steady-state current field analysis and uses the current distribution as the input current distribution, similar to PHICOIL. The current distribution calculation functionality is the same as that of <a href=\"\/product\/EMSolution\/en\/case\/porous_steady-state_current\/\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline\"><font color=\"Red\">&quot;Steady Current Field Analysis&quot;<\/font><\/a>. However, DCCURR can calculate the magnetic field distribution by current distribution and output Joule loss and resistance.<\/p>\n<h3>Explanation<\/h3>\n<p>The model shown in Fig. 1, which simulates a conductor with two branches, is used in the analysis. The two branches have the same geometry, but the conductivity of one side is halved. This is equivalent to doubling the resistance. A DC current of 90 A is applied to the lower surface before the bifurcation as the input current for analysis. Fig. 2 shows the current distribution. If only conductors are analyzed, the <a href=\"\/product\/EMSolution\/en\/case\/porous_steady-state_current\/\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline\"><font color=\"Red\">&quot;Steady Current Field Analysis&quot;<\/font><\/a> function can also be used. It can be confirmed that the current distribution is biased. Calculating the amount of current passing through the branch using the <a href=\"\/product\/EMSolution\/en\/case\/current_through_surface\/\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline\"><font color=\"Red\">&quot;Passing Current Calculation Surface&quot;<\/font><\/a> function, it can be confirmed that the current passes through the conductor at a ratio of approximately 1:2 (Table 1).  <\/p>\n<div class=\"img col2\">\n<div>\n        <a href=\"\/product\/EMSolution\/en\/wp-content\/uploads\/bulk_steady_current01.png\" class=\"modal\"><br \/>\n        <img decoding=\"async\" src=\"\/product\/EMSolution\/en\/wp-content\/uploads\/bulk_steady_current01.png\" alt=\"\" \/><\/a><br \/>\n<!--        \n\n<p class=\"text01\">Fig.1\u3000\u4e8c\u5206\u5c90\u5c0e\u4f53\u30e2\u30c7\u30eb<br \/>\uff08\u7a7a\u6c17\u9818\u57df\u3092\u9664\u304f\uff09<\/p>\n\n--><\/p>\n<p style=\"text-align:center\">Fig.1 Bifurcated conductor model<br \/>(excluding air region)<\/p>\n<\/p><\/div>\n<div>\n        <a href=\"\/product\/EMSolution\/en\/wp-content\/uploads\/bulk_steady_current02.png\" class=\"modal\"><br \/>\n        <img decoding=\"async\" src=\"\/product\/EMSolution\/en\/wp-content\/uploads\/bulk_steady_current02.png\" alt=\"\" \/><\/a><br \/>\n<!--        \n\n<p class=\"text01\">Fig.2\u3000\u96fb\u6d41\u5bc6\u5ea6\u30d9\u30af\u30c8\u30eb\u5206\u5e03 ($A\/m^2$)<\/p>\n\n--><\/p>\n<p style=\"text-align:center\">Fig.2 Current density vector distribution ($A\/m^2$)<\/p>\n<\/p><\/div>\n<\/div>\n<h2 id=\"tablepress-4-name\" class=\"tablepress-table-name tablepress-table-name-id-4\">Table 1 Pass-through current and heat generation<\/h2>\n\n<table id=\"tablepress-4\" class=\"tablepress tablepress-id-4\" aria-labelledby=\"tablepress-4-name\">\n<tbody>\n<tr class=\"row-1\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Right Branch<\/td><td class=\"column-3\">Left Branch<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Currency current amount<\/td><td class=\"column-2\">30.66 $A$<\/td><td class=\"column-3\">59.34 $A$<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">calorific value<\/td><td class=\"column-2\">0.175 $W$<\/td><td class=\"column-3\">0.328 $W$<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">resistance<\/td><td class=\"column-2\">1.86e4 $\u03a9$<\/td><td class=\"column-3\">0.931e4 $\u03a9$<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-4 from cache -->\n<p>The amount of heat generation can be output for each part in the series for each series as shown below using the <a href=\"\/product\/EMSolution\/en\/case\/source_output_heat\/\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline\"><font color=\"Red\">&quot;Heat generation value output for magnetic field source&quot;<\/font><\/a> function. If you want to calculate the resistance for each area, you can use the heat generation value $Q$ for each area to calculate $R=Q\/I^2$. Fig. 4 shows the magnetic flux density distribution due to conductor current.  <\/p>\n<p>Output of Heat Generation<\/p>\n<p class=\"slideText\">***    Joule loss in sources   ********************<br \/>\n  ID No.          Q (W)<br \/>\n    1           7.3314e-01<br \/>\n  ( 1 )         2.2310e-01<br \/>\n  ( 2 )         1.7740e-01<br \/>\n  ( 3 )         3.3264e-01<br \/>\n*************************************************\n<\/p>\n<div class=\"img col1\">\n<div>\n        <a href=\"\/product\/EMSolution\/en\/wp-content\/uploads\/bulk_steady_current03.png\" class=\"modal\"><br \/>\n        <img decoding=\"async\" src=\"\/product\/EMSolution\/en\/wp-content\/uploads\/bulk_steady_current03.png\" alt=\"\" \/><\/a><br \/>\n<!--        \n\n<p class=\"text01\">Fig.3\u3000\u78c1\u675f\u5bc6\u5ea6\u30d9\u30af\u30c8\u30eb\u5206\u5e03 [T]<br \/><small>\uff0a\u30d7\u30ed\u30d1\u30c6\u30a3\u8868\u9762\u306e\u307f<\/small><\/p>\n\n--><\/p>\n<p style=\"text-align:center\">Fig.3 Magnetic flux density vector distribution [T]<br \/>*Property surface only<\/p>\n<\/p><\/div>\n<\/div>\n<p>Briefly, we introduced the DC current field analysis of bulk conductors. This function can be used to obtain the DC current distribution of a bulk conductor and the resulting magnetic field distribution. It can also be used as an initial value for transient analysis involving eddy currents in conductors. In this case, the current field source is set to <a href=\"\/product\/EMSolution\/en\/case\/sufcur\/\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline\"><font color=\"Red\">&quot;SUFCUR&quot;<\/font><\/a> and the element properties must be set as conductors.<\/p>\n<p><!--more--><\/p>\n<h3>How to use<\/h3>\n<p>Define &quot;DCCURR&quot; as the current field source as follows  <\/p>\n<p class=\"slideText\">* SOURCES Definitions *<br \/>\n              SOURCE<br \/>\n* DCCURR * SERIES_NO * NO_PARTS * IN_ROTOR *<br \/>\n   DCCURR             1                     3                     0<br \/>\n* MAT_ID * SMAT_ID * CURENT *  SIGMA  *<br \/>\n      1                 10                1         1.0e+008<br \/>\n* MAT_ID *   SIGMA   *<br \/>\n      2            5.0e+007<br \/>\n      3            1.0e+008\n<\/p>\n<p>You can set as many conductors as you set in NO_PARTS, where MAT_ID is the solid conductor property, SMAT_ID is the current input surface, CURRENT is the normalized current amount, and SIGMA is the conductivity. For the second and subsequent conductors, only MAT_ID and SIGMA can be set. SIGMA must be set. Input current should be set in CIRCUIT or NETWORK. If there are two or more independent conductors, define multiple DCCURRs. By setting HEAT=1, the heat value and heat density for each element are output in the HEAT file and the heat value in the OUTPUT file.<\/p>\n<h3>Download<\/h3>\n<p><button type=\"button\" class=\"btn btn-danger btn-lg\"><a href=\"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-content\/uploads\/bulk_steady_current.zip\">Sample data DL<\/a><\/button>  <\/p>\n<p>\u30fb input3D_DCCURR.ems<br \/>\n\u30fb inputRestart3D_SUFCUR.ems<br \/>\n\u30fb pre_geom2D.neu \uff1aMesh file<br \/>\n\u30fb 2D_to_3D \uff1a2D mesh extension file  <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Summary For analysis of bulk conductors, including eddy currents, &quot;SUFCUR&quot; is available. However, SUFCUR cannot be used in static magnetic field analysis (STATIC). For STATIC, &quot;PHICOIL&quot; can be used as a similar function, but it is designed for coils and cannot be applied to conductors in contact with members with different conductivities. We now introduce [&hellip;]<\/p>\n","protected":false},"featured_media":0,"template":"","tags":[],"case_cat":[2],"class_list":["post-93","case","type-case","status-publish","hentry","case_cat-denjiba"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case\/93"}],"collection":[{"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case"}],"about":[{"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/types\/case"}],"version-history":[{"count":7,"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case\/93\/revisions"}],"predecessor-version":[{"id":2845,"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case\/93\/revisions\/2845"}],"wp:attachment":[{"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/media?parent=93"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/tags?post=93"},{"taxonomy":"case_cat","embeddable":true,"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case_cat?post=93"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}