{"id":216,"date":"2022-09-20T14:03:57","date_gmt":"2022-09-20T05:03:57","guid":{"rendered":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en2\/?post_type=case&#038;p=216"},"modified":"2022-09-20T16:46:16","modified_gmt":"2022-09-20T07:46:16","slug":"steady-current-temp","status":"publish","type":"case","link":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/case\/steady-current-temp\/","title":{"rendered":"Analysis using temperature-dependent conductivity"},"content":{"rendered":"<h3>Summary<\/h3>\n<p>Conductivity is known to be temperature-dependent, and we have added the new function to analyze using temperature-dependent conductivity. Eddy current analysis can be performed by setting the conductivity-temperature curve and the temperature of element or property.  <\/p>\n<h3>Explanation<\/h3>\n<p>his function is illustrated using a model simulating a bifurcated conductor as shown in Fig. 1, which was used in the <a href=\"\/product\/EMSolution\/en\/case\/bulk-steady-current\/\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline\"><font color=\"Red\">&quot;DC Current Field Analysis of Bulk Conductors&quot;<\/font><\/a>. The two bifurcations have the same geometry, but the conductivity at one side is smaller than the other, assuming that the temperature rises on that side. Fig. 2 shows the temperature vs. conductivity curve used in the analysis. Please note that the temperature rise is assumed to be very short, but this is for sample calculations.<br \/>\nFig.3 shows the current distribution at times 0.001s, 0.005s, and 0.01s. You can see that the left branch is gradually approaching a steady state because the conductivity does not change, while the right branch, on the contrary, shows a decrease in current due to the change in conductivity. The temperature-dependent conductivity analysis function uses interpolation from the conductivity-temperature curve. The temperature can be specified on an element-by-element or property-by-property basis, and the temperature at each time must be set in a separate file &quot;temperature.dat&quot;.  <\/p>\n<div class=\"img col2\">\n<div>\n        <a href=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp01.png\" class=\"modal\"><br \/>\n        <img decoding=\"async\" src=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp01.png\" alt=\"\" \/><\/a><br \/>\n<!--        \n\n<p class=\"text01\">Fig.1\u3000\u4e8c\u5206\u5c90\u5c0e\u4f53\u30e2\u30c7\u30eb<br \/>\uff08\u7a7a\u6c17\u9818\u57df\u3092\u9664\u304f\uff09<\/p>\n\n--><\/p>\n<p style=\"text-align:center\">Fig.1 Bifurcated conductor model<br \/> (excluding air region)<\/p>\n<\/p><\/div>\n<div>\n        <a href=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp02.png\" class=\"modal\"><br \/>\n        <img decoding=\"async\" src=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp02.png\" alt=\"\" \/><\/a><br \/>\n<!--        \n\n<p class=\"text01\">Fig.2\u3000\u6e29\u5ea6\u4f4d-\u5c0e\u96fb\u7387\u66f2\u7dda<\/p>\n\n--><\/p>\n<p style=\"text-align:center\">Fig.2 Temperature variation with time<\/p>\n<\/p><\/div>\n<\/div>\n<div class=\"img col2\">\n<div>\n        <a href=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp03.png\" class=\"modal\"><br \/>\n        <img decoding=\"async\" src=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp03.png\" alt=\"\" \/><\/a><br \/>\n<!--        \n\n<p class=\"text01\">\uff08a\uff090.001\u79d2<\/p>\n\n--><\/p>\n<p style=\"text-align:center\">(a) 0.001 sec.<\/p>\n<\/p><\/div>\n<div>\n        <a href=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp04.png\" class=\"modal\"><br \/>\n        <img decoding=\"async\" src=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp04.png\" alt=\"\" \/><\/a><br \/>\n<!--        \n\n<p class=\"text01\">\uff08b\uff090.005\u79d2<\/p>\n\n--><\/p>\n<p style=\"text-align:center\">(b) 0.005 sec.<\/p>\n<\/p><\/div>\n<\/div>\n<div class=\"img col1\">\n<div>\n        <a href=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp05.png\" class=\"modal\"><br \/>\n        <img decoding=\"async\" src=\"\/product\/EMSolution\/en\/wp-content\/uploads\/steady_current_temp05.png\" alt=\"\" \/><\/a><br \/>\n<!--        \n\n<p class=\"text01\">\uff08c\uff090.010\u79d2<\/p>\n\n--><\/p>\n<p style=\"text-align:center\">(c) 0.010 sec.<\/p>\n<\/p><\/div>\n<p><!--\n\n<p class=\"caption\">Fig.3 \u96fb\u6d41\u5bc6\u5ea6\u30d9\u30af\u30c8\u30eb\u5206\u5e03\uff08$A\/m^2$\uff09<\/p>\n\n--><\/p>\n<p class=\"caption\">Fig.3 Current density vector distribution ($A\/m^2$)<\/p>\n<\/div>\n<p>Briefly, we have introduced an analysis that takes into account the temperature dependence of conductivity. This function can be used for transient analysis of bulk conductors using SUFCUR. It can also be used for &quot;steady-state current field analysis&quot; (Handbook &quot;2. Types of Analysis&quot;). Basically, conductivity-temperature curves are used, but may also be used when conductivity depends on factors other than temperature.  <\/p>\n<p><!--more--><\/p>\n<h3>How to use<\/h3>\n<p>The TEMP_DEPEND module is required to use the temperature-dependent conductivity analysis function.  <\/p>\n<p class=\"slideText\"><span>* STATIC * STEP * AC * TRANSIENT * DISPLACEMENT * NON_LINEAR <font color=\"Red\">* TEMP_DEPEND *<\/font> STEADY_CURRENT *<\/span><br \/>\n<span>        0            0         0              1                       0                            0                              <font color=\"Red\">1<\/font>                          0 <\/span>\n<\/p>\n<p>Set the ID of the temperature-dependent conductivity curve described below to the new option SIGMA_DEPEND_ID in Handbook &quot;16.1.1 Element Volume Characteristics&quot;. If SIGMA_DEPEND_ID&gt;0, the value of SIGMA is not used.  <\/p>\n<p class=\"slideText\"><span>* MAT_ID * POTENTIAL * BH_CURVE_ID *     SIGUMA     *     MU     * PACKING * ANISOTROPY * IRON_LOSS <font color=\"Red\">* SIGMA_DEPEND_ID *<\/font><\/span><br \/>\n<span>         1                 0                         0                    1e+008               1                1                   0                        0                            <font color=\"Red\">1<\/font><\/span>\n<\/p>\n<p>The conductivity-temperature curve would be set to the new NO_SIGMA_DEPENDENT_CURVES.  <\/p>\n<ul>\n<li>\n<p>CURVE_ID\uff1aConductivity-temperature curve ID<\/p>\n<\/li>\n<li>\n<p>NO_DATA\uff1aNumber of data points<\/p>\n<\/li>\n<li>\n<p>TYPE=0\uff1aDefault<\/p>\n<\/li>\n<li>\n<p>TEMPERATURE\uff1aTemperature (&#8451;)<\/p>\n<\/li>\n<li>\n<p>SIGMA\uff1aConductivity ($S\/m$)<\/p>\n<p>The temperature for each element is specified in temperature.dat. The version number at the beginning of the input file must be &quot;r12.0&quot; or higher.<\/p>\n<\/li>\n<li>\n<p>NO_STEP\uff1aNumber of steps to set temperature  <\/p>\n<\/li>\n<li>\n<p>TYPE=0\uff1aTemperature is set for each element.<br \/>\n\u3000\u3000=1\uff1aTemperature is set for each property.  <\/p>\n<\/li>\n<li>\n<p>NO_DATA\uff1aNumber of elements to be set for TYPE=0, number of properties to be set for TYPE=1  <\/p>\n<\/li>\n<li>\n<p>INPUT_TYPE=0\uff1a Fixed  <\/p>\n<\/li>\n<li>\n<p>FORMAT =0\uff1aSet in the format described below.<br \/>\n\u3000\u3000\u3000\u3000=1\uff1aSet in ATLAS format; only used in case of TYPE=0.  <\/p>\n<\/li>\n<li>\n<p>REDIRECT=0\uff1aOutput the contents of temperature.dat to the check file.<br \/>\n\u3000\u3000\u3000\u3000=1\uff1aDo not output to the check file.  <\/p>\n<\/li>\n<li>\n<p>IDS\uff1aElement number (TYPE=0) or property number (TYPE=1)  <\/p>\n<\/li>\n<li>\n<p>TIME\uff1aTime, to be set to include the computed time of the input file.  <\/p>\n<\/li>\n<li>\n<p>IDS\uff1aTemperature \uff08&#8451;\uff09  <\/p>\n<\/li>\n<\/ul>\n<p class=\"slideText\"><span><font color=\"Red\">* NO_SIGMA_DEPENDENT_CURVES *<\/font><\/span><br \/>\n<span><font color=\"Red\">                                1              <\/font><\/span><br \/>\n<span><font color=\"Red\">* CURVE_ID * NO_DATA * TYPE *<\/font><\/span><br \/>\n<span><font color=\"Red\">          1                     6              0   <\/font><\/span><br \/>\n<span><font color=\"Red\">* TEMPERATURE * SIGMA *<\/font><\/span><br \/>\n<span><font color=\"Red\">            0                   1e+008<\/font><\/span><br \/>\n<span><font color=\"Red\">           20                  1e+008<\/font><\/span><br \/>\n<span><font color=\"Red\">           40                  5e+007<\/font><\/span><br \/>\n<span><font color=\"Red\">           60                  5e+007<\/font><\/span><br \/>\n<span><font color=\"Red\">           80                 2.5e+007<\/font><\/span><br \/>\n<span><font color=\"Red\">          100                2.5e+007<\/font><\/span>\n<\/p>\n<h3>Download<\/h3>\n<h4>Bifurcated conductor model\u3000\u3000<button type=\"button\" class=\"btn btn-danger btn-lg\"><a href=\"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-content\/uploads\/simplified_eec.zip\">Sample data DL<\/a><\/button><\/h4>\n<p>\u30fb input3D_SUFCUR_tempDepend.ems<br \/>\n\u30fb pre_geom2D.neu<br \/>\n\u30fb 2D_to_3D<br \/>\n\u30fb temperature.dat  <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Summary Conductivity is known to be temperature-dependent, and we have added the new function to analyze using temperature-dependent conductivity. Eddy current analysis can be performed by setting the conductivity-temperature curve and the temperature of element or property. Explanation his function is illustrated using a model simulating a bifurcated conductor as shown in Fig. 1, which [&hellip;]<\/p>\n","protected":false},"featured_media":0,"template":"","tags":[],"case_cat":[22],"class_list":["post-216","case","type-case","status-publish","hentry","case_cat-tyokuryu"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case\/216"}],"collection":[{"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case"}],"about":[{"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/types\/case"}],"version-history":[{"count":6,"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case\/216\/revisions"}],"predecessor-version":[{"id":2679,"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case\/216\/revisions\/2679"}],"wp:attachment":[{"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/media?parent=216"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/tags?post=216"},{"taxonomy":"case_cat","embeddable":true,"href":"https:\/\/www.ssil.co.jp\/product\/EMSolution\/en\/wp-json\/wp\/v2\/case_cat?post=216"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}